HCM(ZQC)
G2R-1-S
Delivery time:in stock
Degree of protection | Closed type (cover) | |
---|---|---|
Terminal structure | Plug-in terminal | |
Coil | Coil ratings | 24 VDC 21.6 mA |
Coil resistance | 1113 Ω | |
Operate voltage (Set voltage) | 70% max. | |
Release voltage (Reset voltage) | 15% min. | |
Maximum voltage | 110% | |
Power consumption | Approx. 0.53 W | |
Contact | Contact rated load |
250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Resistive load) 30 VDC 5 A (Inductive load (L/R = 7 ms)) |
Max. contact voltage |
440 VAC 125 VDC |
|
Max. contact current |
AC: 10 A DC: 10 A |
|
Maximum switching power |
2500 VA (Resistive load) 1875 VA (Inductive load (cosφ = 0.4)) 300 W (Resistive load) 150 W (Inductive load (L/R = 7 ms)) |
|
Contact form | SPDT | |
Contact method | Single | |
Contact material | Ag alloy |
Contact resistance | 30 mΩ max. (Voltage drop method with 5 VDC 1 A) |
---|---|
Operating time | 15 ms max. (With rated operating power applied, not including contact bounce) |
Reset time | 5 ms max. (With rated operating power applied, not including contact bounce) |
Maximum operating frequency |
Mechanical: 18000 time/h Rated load: 1800 time/h |
Insulation resistance |
Between coil and contacts: 1000 MΩ min. (at 500 VDC) Between contacts of same polarity: 1000 MΩ min. (at 500 VDC) |
Dielectric strength |
Between coil and contacts: 5000 VAC 50/60 Hz 1 min Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min |
Vibration resistance (destruction) | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Vibration resistance (Malfunction) | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Shock resistance (destruction) | 1000 m/s2 |
Shock resistance (Malfunction) |
Energized: 200 m/s2 No energized: 100 m/s2 |
Endurance (Mechanical) | 20 million operations min. (switching frequency 18,000 operations/h) |
Endurance (Electrical) | 100,000 operations min. (Rated load, switching frequency 1,800 operations/h) |
Failure rate | 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute) |
Ambient temperature (Operating) | -40 to 70℃ (with no freezing or condensation) |
Ambient humidity (Operating) | 5 to 85% |
Weight | Approx. 20 g |
Mounting method | Socket |