HCM(YL)
DFS60B-BGEM01024
Delivery time:8-14 weeks
| Pulses per revolution | 1,024 1) |
| Measuring step | 90° electric/pulses per revolution |
| Measuring step deviation at binary number of lines | ± 0.008° |
| Error limits | ± 0.05° |
| Communication interface | Incremental |
| Communication Interface detail | HTL / Push pull |
| Number of signal channels | 6-channel |
| Initialization time | 40 ms |
| Output frequency | ≤ 600 kHz |
| Load current | ≤ 30 mA |
| Power consumption | ≤ 0.5 W (without load) |
| Connection type | Cable, 8-wire, universal, 5 m 1) |
| Supply voltage | 10 ... 32 V |
| Reference signal, number | 1 |
| Reference signal, position | 90°, electric, logically gated with A and B |
| Reverse polarity protection | ✔ |
| Short-circuit protection of the outputs | ✔ 2) |
| MTTFd: mean time to dangerous failure | 300 years (EN ISO 13849-1) 3) |
| Mechanical design | Blind hollow shaft |
| Shaft diameter | 14 mm |
| Weight | + 0.2 kg |
| Shaft material | Stainless steel |
| Flange material | Aluminum |
| Housing material | Aluminum die cast |
| Start up torque | 0.8 Ncm (+20 °C) |
| Operating torque | 0.6 Ncm (+20 °C) |
| Permissible movement static |
± 0.3 mm (radial) ± 0.5 mm (axial) |
| Permissible movement dynamic |
± 0.2 mm (radial) ± 0.1 mm (axial) |
| Operating speed | ≤ 6,000 min⁻¹ 1) |
| Moment of inertia of the rotor | 40 gcm² |
| Bearing lifetime | 3.6 x 10^10 revolutions |
| Angular acceleration | ≤ 500,000 rad/s² |
| EMC | According to EN 61000-6-2 and EN 61000-6-4 |
| Enclosure rating |
IP67, housing side, cable connection (IEC 60529) IP65, shaft side (IEC 60529) |
| Permissible relative humidity | 90 % (Condensation not permitted) |
| Operating temperature range |
–40 °C ... +100 °C 1) –30 °C ... +100 °C 2) |
| Storage temperature range | –40 °C ... +100 °C, without package |
| Resistance to shocks | 70 g, 6 ms (EN 60068-2-27) |
| Resistance to vibration | 30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) |