HCM
DBS60E-BGAC02048
Delivery time:in stock
performance
Pulse per revolution 2048
Measurement step distance ≤ 90 ° electricity/number of pulses per revolution
Measurement step deviation ± 18 °/pulse per revolution
Error limit measurement pulse width deviation x 3
Duty cycle ≤ 0.5 ± 5%
Interface
Incremental communication interface
Communication interface details TTL/RS-422
Number of signal channels 6 channels
Initialization time<5 ms 1)
Output frequency+300 kHz 2)
Load current ≤ 30 mA, per channel
Working current ≤ 50 mA (no load)
1) Afterwards, a valid signal can be read
2) Customizable up to 450 kHz according to requirements
Electrical parameters
Connection type plug, M12, 8-pin, radial
Supply voltage 4.5... 5.5 V
Reference signal, quantity 1
Reference signal, position 90 °, electrical, logically connected to A and B
Polarity reversal protection ✔
Output short circuit protection ✔ 1)
MTTFd: Time between dangerous faults 500 years (EN ISO 13849-1) 2)
1) Short circuit to another channel or GND, with a maximum allowable time of 60 seconds. US channel short circuit is not protected
2) This product is a standard product, not a safety component made according to mechanical instructions. Calculate the component based rated load, average ambient temperature of 40 ° C, and usage frequency of 8760 hours per year. All electronic faults are considered dangerous faults. For detailed information, please refer to document number 8015532
Mechanical parameters
Mechanical specifications blind hole hollow shaft
Shaft diameter 14 mm
Flange type/stator coupling Double sided stator coupling, long hole, hole circle 63mm – 83mm
Weight+0.25 kg 1)
Material, shaft stainless steel
Material, flange aluminum
Material, housing aluminum
Starting torque+0.5 Ncm (+20 ° C)
Working torque 0.4 Ncm (+20 ° C)
Allow static axis displacement
± 0.3 mm (radial)
± 0.5 mm (axial) 2)
Allow dynamic axis displacement
± 0.1 mm (radial)
± 0.2 mm (axial) 2)
Working speed 6000 min ⁻ ¹ 3)
Maximum working speed 9000 min ⁻ ¹ 4)
Rotational inertia 50 gcm ²
Bearing service life 3.6 x 109 revolutions
Angular acceleration ≤ 500000 rad/s ²
1) Suitable for encoders with plugs or cables with plugs
2) Not applicable to stator couplings C and K
3) When designing the operating temperature range, attention should be paid to the self heating of 2.6 K/1000 rpm
4) The maximum speed that will not cause mechanical failure of the encoder. May affect service life and signal quality. Please pay attention to the maximum output frequency
Environmental parameters
Electromagnetic compatibility according to EN 61000-6-2 and EN 61000-6-3
Shell protection level
IP67, shell side (IEC 60529) 1)
IP65, shaft side (IEC 60529)
Permissible relative humidity of 90% (condensation not allowed)
Operating temperature range -20 ° C+ 85 °C 2)
Storage temperature range -40 ° C+ 100 ° C, unpackaged
Impact resistance 250 g, 3 ms (EN 60068-2-27)
Vibration resistance 30 g, 10 Hz 2,000 Hz (EN 60068-2-6)
1) Install the matching connector
2) Unless otherwise specified, this value corresponds to all mechanical forms including recommended accessories