LC1D258F7
1
  • LC1D258F7
2
views: 1016

LC1D258F7

Rate:
0.0000/5

( 0 reviews )

Item NO.: V030699 MOQ: 0
Weight:    0.5kgs
Package Size:  91*45*99mm
 Price:
$60.70
 Qty:
      $60.70
 Shipping:   Calculate Shipping Cost

HCM(ZQC)

LC1D258F7

Delivery time:8-9 weeks


Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

Main
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
AC-3
AC-3e
AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current 40 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 2 NO + 2 NC
Contact compatibility M6
Protective cover With
[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit
40 A 140 °F (60 °C) power circuit
Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
450 A 440 V power circuit IEC 60947
Rated breaking capacity 450 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current 240 A 104 °F (40 °C) - 10 s power circuit
380 A 104 °F (40 °C) - 1 s power circuit
50 A 104 °F (40 °C) - 10 min power circuit
120 A 104 °F (40 °C) - 1 min power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
Associated fuse rating 10 A gG signalling circuit IEC 60947-5-1
63 A gG <= 690 V type 1 power circuit
40 A gG <= 690 V type 2 power circuit
Average impedance 2 mOhm - Ith 40 A 50 Hz power circuit
Power dissipation per pole 3.2 W AC-1
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 1.4 Mcycles 40 A AC-1 <= 440 V
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc -40…140 °F (-40…60 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz
Inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C))
70 VA 50 Hz 0.75 68 °F (20 °C))
Hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C))
7 VA 50 Hz 0.3 68 °F (20 °C))
Heat dissipation 2…3 W 50/60 Hz
Operating time 12...22 ms closing
4...19 ms opening
Maximum operating rate 3600 cyc/h 140 °F (60 °C)
Connections - terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible with cable end
Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…16 mm²) solid without cable end
Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…16 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.93 lbf.in (1.8 N.m) screw clamps terminals flat Ø 6 mm
Power circuit 15.93 lbf.in (1.8 N.m) screw clamps terminals Philips No 2
Power circuit 15.93 lbf.in (1.8 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V signalling circuit
Minimum switching current 5 mA signalling circuit
Insulation resistance > 10 MOhm signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Rail
Plate
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product Certifications UL
CSA
CCC
EAC
UKCA
CB
EU-RO-MR by DNV-GL
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude 0...9842.52 ft (0...3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz)
Vibrations contactor closed 4 Gn, 5...300 Hz)
Shocks contactor closed 15 Gn for 11 ms)
Shocks contactor open 8 Gn for 11 ms)

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$66.50
$275.50
$49.00
$11.00
$86.00
$39.00
$1413.10
$21.00
$28.50
Business time
9:00-22:00
  • Email:support@rig123.com