supply voltage


Rated value (DC)


● DC 24 V Yes


Load voltage L+


● Rated value (DC) 24 V


● Allowable range, lower limit (DC) 20.4 V


● Allowable range, upper limit (DC) 28.8 V


Input current


Turn on the current, with a maximum value of 12 A; At 28.8 V


From the power supply voltage L+, * * * with a maximum value of 700 mA; 110 mA to 700 mA, 660 mA for expansion component output current (5 V DC)


Sensor power supply


24 V sensor supply


● 24 V Yes; Allowable range: 15.4 to 28.8 V


● Short circuit protection Yes; Electronic at 280 mA


● Output current, * * * maximum 280 mA


Power loss


Power loss, typical value 7 W


storage


Number of memory modules (optional) 1; A pluggable memory module with the same content as the integrated EEPROM. It can also store recipes, data records, and other files by category.


Working memory


● Integration (for programs) 12 kbyte; 8 KB when runtime editing is activated


● Integration (for data) 8 kbyte


buffer


● Existence Yes; Program: The entire program is located in the integrated EEPROM, maintenance free, and can be programmed through the CPU; Data: The entire DB 1 downloaded from PG/PC is located in the integrated EEPROM and is maintenance free. The real-time values of DB 1 are located in RAM, and the remaining tags, timers, counters, etc. are maintenance free through * * capacitors; Optional battery for long buffer


Battery


Buffer battery


● Buffer time, * * * with a maximum of 100 h; (at least 70 hours at 40 ° C); 200 days (typical) with optional battery modules


CPU processing time


For bit operations, the * * * large value is 0.22 µ s


Counters, timers, and their remanence


S7 counter


● Quantity 256


remanence


- adjustable Yes; About * * capacitors or batteries


- Lower limit 1


- Upper limit 256


Counting range


- Lower limit 0


- Upper limit 32 767


S7 time


● Quantity 256


remanence


- adjustable Yes; About * * capacitors or batteries


- Upper limit 64


time frame


- Lower limit 1 ms


- Upper limit 54 min; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 timers: 100 ms to 54 min


Data range and its remanence


sign


● Capacity, * * * max 32 bytes


● Presence of residual magnetism Yes; M 0.0 to M 31.7


● Keep 0 to 255 with batteries, adjustable for * * capacitors or batteries


● Keep 0 to 112 in the EEPROM without batteries, adjustable


Hardware expansion


Number of expansion brackets, * * * maximum 7; Only S7-22x series expansion modules can be used. Due to limited output current, the use of expansion modules may be limited.


Connectable programming device/PC SIMATIC PG/PC, standard PC


Expansion module


● Analog input/output terminal, * * * large value 35*** Large 28 inputs and 7 outputs (EM) or * * * Large 0 inputs and 14 outputs (EM)


● Digital input/output terminal, * * * large value 168*** 94 more inputs and 74 outputs (CPU+EM)


● AS interface input/output terminal, * * * large value 62; AS interface A/B slave station (CP 243-2)


Digital input


Number of digital inputs 14


Source type input/drain type input Yes; Optional, each group


input voltage


● Rated value (DC) 24 V


● 0 to 5 V for signal "0"


● For signal "1" * * *, the minimum value is 15 V


Input current


● Typical value of 2.5 mA for signal "1"


Input delay (when the input voltage is rated)


For standard inputs


- Parameterizable Yes; whole


- From "0" to "1", * * * has a small value of 0.2 ms


- From "0" to "1", * * * has a maximum value of 12.8 ms


For alarm inputs


- Parameterizable Yes; E 0.0 to E 0.3


For technical functions


- Parameterizable Yes; (E 0.0 to E 1.5) 30 kHz


Wire length


● Shielding, * * * with a maximum of 500 m; Standard entrance: 500 m, fast counter: 50 m


● Unshielded, * * * with a maximum of 300 m; Not used for high-speed signals


Digital output


Number of digital outputs 10; transistor


Short circuit protection or not; External Presets


Limit of inductive switching off voltage 1 W


Making and breaking capacity of output terminal


● Maximum value of 0.75 A under resistive load


● Maximum value of 5 W at lighting load


output voltage


● For signal "1", * * * small value DC 20 V


Output current


● Rated value of 750 mA for signal "1"


● For the residual current of signal "0", the maximum value of * * * is 10 µ A


Output delay under resistive load


● From "0" to "1", * * * has a maximum value of 15 µ s; Standard output, * * * large values (A 0.2 to A 1.1) 2 µ s; Pulse output, * * * maximum (A 0.0 to A 0.1) 2 µ s


● From "1" to "0", * * * has a maximum value of 130 µ s; Standard output, * * * large values (A 0.2 to A 1.1) 10 µ s; Pulse output, * * * maximum (A 0.0 to A 0.1) 10 µ s


Two outputs in parallel


● Used to increase power Yes


switching frequency


● Pulse output terminal of resistive load, with a maximum value of 20 kHz; A 0.0 to A 0.1


Total current at the output (per group)


All installation locations


- * * * Up to 40 ℃, * * * Maximum 6 A


Horizontal installation position


- * * * Up to 55 ℃, * * * Maximum 6 A


Relay output terminal


● Number of relay outputs 0


Wire length


● Shielding, * * * max 500 m


● Unshielded, * * * max 150 m


Analog Input


Number of analog potentiometers 2; Analog potentiometer; Resolution 8 bits


sensor


Connectable sensor


● Two wire sensor Yes


- Allowable closed circuit current (dual wire sensor) * * * Maximum 1 mA


1. Interface


Interface type Integrated RS 485 interface


agreement


● MPI Yes; As an MPI slave station, it is used for data exchange with the MPI master station (S7-300/S7-400-CPU, OP, TD, push button panel); The internal CPU/CPU communication of S7-200 may be limited in the MPI network; Transmission rate 19.2/187.5 kbit/s


● PPI Yes; PPI protocol is attached for programming functions, HMI functions (TD 200, OP), and internal CPU/CPU communication of S7200; Transmission rate 9.6/19.2/187.5 kbit/s


● Serial data exchange Yes; As a freely programmable interface, external devices with ASCII protocol baud rate are used for serial data exchange: 1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2 kbps; PC/PPI cables can also be used as RS 232/RS 485 converters


MPI


● Transmission rate, * * * minimum 19.2 kbit/s


● Transmission rate, * * * with a maximum of 187.5 kbit/s


Integrated functionality


Number of alarm inputs 4; 4 rising pulses and/or 4 falling pulses


The number of pulse output terminals 2; Fast output terminal, 20 kHz, with possibility of interruption; Pulse wavelength and frequency can be modulated


Limit frequency (pulse) 20 kHz


Potential isolation


Digital input potential isolation


● Between channels is


● Between channels, group points 6 and 8


Digital output potential isolation


● Yes between channels; Photocoupler


● Between channels, the number of grouping points is 5


Allowable potential difference


Between different circuits DC 500 V between DC 24 V and DC 5 V


Protection level and protection category


Protection grade IP IP20


Environmental requirements


Ambient temperature during operation


● Horizontal installation, * * * minimum value 0 ° C


● Horizontal installation, * * * maximum 55 ° C


● Vertical installation, * * * minimum value 0 ° C


● Vertical installation, * * * maximum 45 ° C


Air pressure meets the requirements of IEC 60068-2-13 standard


● Allowable range, lower limit 860 hPa


● Allowable range, upper limit 1 080 hPa


Relative air humidity


● Operation, * * * small value 5%


● Operation, * * * maximum 95%; RH stress intensity 2 in accordance with IEC 1131-2


Project Configuration/Title


Project Configuration/Programming/Title


● Operate standby devices for binary operations, comparison operations, time operations, count operations, clock operations, transmission operations, table operations, logic operations, movement and rotation operations, conversion operations, program control operations, interrupt and communication operations, stack operations, fixed point operations, floating point operations, and digital functions


● Program editing free cycle (OB 1), alarm control, time control (1 to 255 ms)


● Program organization 1 OB, 1 DB, 1 SDB subroutines with/without parameter transmission


● Number of subprograms, * * * large value 64


programming language


- KOP Yes


- FUP is


- AWL is


Technical protection


● User program protection/password protection Yes; Level 3 password protection


Connection Technology/Title


Pluggable I/O terminals are


size


Width 120.5 mm


Height 80 mm


Depth 62 mm

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Related tools
$357.50
$357.50
$105.50
$219.50
$204.50
$163.50
$163.50
Business time
9:00-22:00
  • Email:support@rig123.com