2904601
1
  • 2904601
2
views: 275

2904601

Rate:
0.0000/5

( 0 reviews )

Item NO.: V029312 MOQ: 0
Weight:    5kgs
Package Size:  
 Price:
$176.00
 Qty:
      $176.00
 Shipping:   Calculate Shipping Cost

ZXG

2904601

Delivery date: spot

Control input (configurable) Rem Output Power ON/OFF (SLEEP MODE)
Default (value) Output power ON (>40 kΩ/24 V DC/Rem and SGnd open bridging)
AC operation
Network type Star Network
Rated input voltage range 100 V AC... 240 V AC
Input voltage range 100 V AC... 240 V AC -15 % ... +10 %
Lower the rating < 100 V AC (1 %/V)
Maximum dielectric strength 300 V AC 60 s
Typical voltage of the national grid 120 V AC
230 V AC
The voltage type of the supply voltage AND
Surge current Typical 12 A at 25 °C
Inrush current integration (I2t) < 0.7 A2s
Surge current limit 12 A (1 ms后)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
16.7 Hz (according to EN 50163)
Grid buffer time 42 ms typical (120 V AC)
44 ms typical (230 V AC)
Power consumption 3.4 A (100 V AC)
2.8 A (120 V AC)
1.5 A (230 V AC)
1.5 A (240 V AC)
Rated power consumption 274 VA
Protection circuits transient surge protection; Varistors, gas discharge tubes
Power factor (COS phi) 0.94
Absorption time < 1 s
Typical response time 300 ms (from SLEEP MODE)
Input fuse 8 A (slow fusing, internal)
Recommended input protection circuit breakers 10 A ... 16 A (characteristics B, C, D, K or similar)
PE discharge current < 3.5 mA
0.7 mA (264 V AC,60 Hz)
Direct current operation
Rated input voltage range 110 V DC ... 250 V DC
Input voltage range 110 V DC ... 250 V DC -18 % ... +40 %
Lower the rating < 110 V DC (1 %/v)
The voltage type of the supply voltage DC
Power consumption 3 A (110 V DC)
1.3 A (250 V DC)

efficiency typical 92.5 % (120 V AC)
typical 93.4 % (230 V AC)
Output characteristics U/I Advanced
Smart HICCUP
FUSE MODE
Rated output voltage 24 V DC
Output voltage (USet) setting scope 24 V DC ... 29.5 V DC (constant capacity)
Rated output current (IN 10 A
Static Boost (IStat.Boost) 12.5 A
Dynamic Boost (IDyn.Boost) 20 A (5 s)
Selective fusing (ISFB) 60 A (15 ms)
Thermomagnetic circuit breaker type A1... A6 / B2... B6 / C1... C3 / Z1... Z6
attenuation > 60 °C ... 70 °C (2.5 % / K)
Feedback voltage resistance ≤ 35 V DC
Overvoltage Protection (OVP) at Output ≤ 32 V DC
Control deviations < 0.5 % (static load change 10% ... 90%)
< 4 % (dynamic load change 10% ... 90%,(10 Hz))
< 0.25 % (input voltage varies from ±10 %)
Residual waves < 80 mVSS (Rating)
Short-circuit protection be
Air defense turns be
Output power 240 watts (Printing)
300 watts (Printing)
480 watts (Printing)
Apparent power 336 AND (120 V,UOUT = 24 V,IOUT = static margin)
345 AND (230 V,UOUT = 24 V,IOUT = static margin)
Maximum idle power consumption < 3 W (120 V AC)
< 3 W (230 V AC)
Maximum rated load power loss < 20 W (120 V AC)
< 17 W (230 V AC)
POWER CONSUMPTION SLEEP MODE < 3 W (120 V AC)
< 3 W (230 V AC)
Amplitude factor Typical 1.50 (120 V AC)
Typical 1.67 (230 V AC)
Rise time < 1 s (UOut = 10 % ... 90 %)
Parallel connected Yes, for redundancy and increased capacity
Concatenated be
Signal
The signal is ground SGnd Reference potentials for Out1, Out2, and Rem
Signal Out 1 (configurable)
Digital quantities 24 V DC 20 mA
Default (value) 24 V DC 20 mA 24 V DC,针对UOut > 0.9 x USet
Signal Out 2 (configurable)
Digital quantities 24 V DC 20 mA
mock 4 mA ... 20 mA ±5 % (load ≤400 Ω)
Default (value) 24 V DC 20 mA 24 V DC,针对POut < PN
Signal relay 13/14 (configurable)
Default (value) Close (Uout > 0.9 USet
Digital quantities 24 V DC 1 A
30 V AC/DC 0.5 A

 
No comment