| Specification | DN6 | |
| Installation position | optional, preferably horizontal | |
| Storage temperature range | (℃) | -20〜80 |
| Ambient temperature range (℃) | BY and BDY | -20〜70 |
| BYN and BDYN | -20〜50 | |
| Weight (Kg) | BY and BDY | 2.4 |
| BYN and BDYN | 2.5 | |
|
Model B ( D ) Yand B ( D ) YN
DN6 |
||
|
Measured at (P=1 OObar,Mineral oil HLP4+,40C土5C ) |
|||
| Operating pressure(bar) | PortsP,P1-P2 A1 | -A2 ; B1-B2 | Up to 315 |
| Port T | Up to 50 | ||
|
Highest setting pressure ( bar) |
Pressure class 50 | 50 | |
| Pressure class 100 | 100 | ||
| Pressure class 200 | 200 | ||
| Pressure class 315 | 315 | ||
| The minimum set pressure at zero point | ( bar) | Please see the performance curve | |
| Back pressure of port A | ( bar) | Single zero pressure back to oil tank | |
| Flow of pilot oil | (L/min) | 0.6〜1.2 | |
| Maximum flow | (L/min) | 30 | |
| Pressure fluid | Mineral oil (HL, HLP) to DIN 51 524;For other fluid please consult with us. | ||
| Fluid temp. Range | ( ℃) | -20〜80 | |
| Viscosity range | ( ℃) | 15+380 | |
| Oil cleanliness | (mm2/s ) | Filter is recommended for the highest fluid pollution degree; the lowest specific filtration resistance according to ISO 4406 (C) 20/18/15. | |
| Hysteresis | (%) | Plus-minus 1.5 of the highest adjustable pressure | |
| Repeatability | (%) | Less than plus-minus 2 of the highest adjustable pressure | |
| Linearity | (%) | Plus-minus 3.5 of the highest adjustable pressure | |
| Sel value caused by the manufacturing errors - pressure characteristics curve derivation refertothe characteristics curvewhen pressure rising | BY and BDY( % ) | Plus-minus 2.5 of the highest adjustable pressure | |
| BYN and BDYN( % ) | Plus-minus 1.5 of the highest adjustable pressure | ||
| Phase step corresponding Tu+Tg | 10%-90%( ms ) | Approximately 80 | Depend on the installation |
| 90%-10%( ms ) | Approximately 50 | ||
| Cleanliness | Filter is recommended for the highest fluid pollution degree;the lowest specific filtration resistance according to ISO 4406 (C) 20/18/15. | ||
| Electrical Specification | ||
| Voltage type | Direct Voltage 24V | |
| Controlling current | (mA ) | (Minimum ) 100, ( Maximum ) 1600 |
|
Solenoid coil (Ω) |
20℃ Measuring under | 5.4 |
| Maximum numerical value | 7.8 | |
| Resistance | (%) | 100 |
| Electrical connection see | BY and BDY | Plug to connect DIN 175 301 -803 and ISO 4400 Ocket to connect DIN 175 301-803 and ISO 4400 |
| BYN and BDYN | Plug to connect DIN EN175 301-803 Ocket to connect DINEN175 301-803 | |
| Type of insulation to DIN 40 050 | IP65 has got installed and lockedup plug-in connector | |