Home » News center » Hall Current Sensor ''Type: FR-DCMG-HS4A or Equivalent
Hall Current Sensor ''Type: FR-DCMG-HS4A or Equivalent
      Promulgator :admin      Time:2024-11-18
K9194XA Yokogawa
ZR01A01-05 Yokogawa
EJA110A-EVS4B-35DD/D4 Yokogawa
EJA110A-EMS4B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.27/KN22 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.29 Yokogawa
EJA110A-EMS5B-97NA/KU2/D4+990.29/KN 2.2 Yokogawa
EJA110A-EHS4B-97NA/KU2/D4 Yokogawa
EJA530A-ECS4N-09NF/KU2/C3/M15/T07/N4/D4/Z Yokogawa
EJA110A-EMS4B-97NA/KU2/N5/D4+990.26 Yokogawa
EJA110A-EMS4B-29DD/D4 Yokogawa
EJA220A-EHWA14F4A-99NN/KU2/M14/N4 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.26 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+2X990.28/KN 22/102/ 103 Yokogawa
AFV30D-A41252 Yokogawa
SNB10D-425/CU2N Yokogawa
RAMC01-D4SS-61L1-J90424/A13/A16/A26/VE Yokogawa
2966171 Phoenix Contact
2966207 Phoenix Contact
2980335 Phoenix Contact
2967060 Phoenix Contact
2966728 Phoenix Contact
2321745 Phoenix Contact
2966223 Phoenix Contact
2940391 Phoenix Contact
IS2-EF8050 ABB
IS2-ЕF6060 ABB
IS2-EF8060 ABB
IS2-EF4060 ABB
IS2-EF4050 ABB
IS2-ЕF6050 ABB
2CDS253001R0061 ABB
V18345-20104610010 ABB
2500/6/0.69 ABB
AMI 500LBL VAFH ABB
1SVR730885R3300 ABB
1SVR730774R3300 ABB
1SDA056192R5 ABB
1SVR427065R0000 ABB
SEALING ELEMENT 150577
SEAL PISTON I.D- UPPER 311111
SEAL PISTON I.D- LOWER 30780
SEAL PISTON . O.D 30782
SEAL ADAPTER. I.D -UPPER 31096
SEAL ADAPTER. I.D -LOWER 30771
SEAL ADAPTER O.D 31011
SEAL ADAPTER  TOP 30773
WEAR RING - PISTON 150613
WEAR RING -LOWE HOUSING 150613
K9194XA Yokogawa
ZR01A01-05 Yokogawa
EJA110A-EVS4B-35DD/D4 Yokogawa
EJA110A-EMS4B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.27/KN22 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.29 Yokogawa
EJA110A-EMS5B-97NA/KU2/D4+990.29/KN 2.2 Yokogawa
EJA110A-EHS4B-97NA/KU2/D4 Yokogawa
EJA530A-ECS4N-09NF/KU2/C3/M15/T07/N4/D4/Z Yokogawa
EJA110A-EMS4B-97NA/KU2/N5/D4+990.26 Yokogawa
EJA110A-EMS4B-29DD/D4 Yokogawa
EJA220A-EHWA14F4A-99NN/KU2/M14/N4 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.26 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+2X990.28/KN 22/102/ 103 Yokogawa
AFV30D-A41252 Yokogawa
SNB10D-425/CU2N Yokogawa
RAMC01-D4SS-61L1-J90424/A13/A16/A26/VE Yokogawa
2966171 Phoenix Contact
2966207 Phoenix Contact
2980335 Phoenix Contact
2967060 Phoenix Contact
2966728 Phoenix Contact
2321745 Phoenix Contact
2966223 Phoenix Contact
2940391 Phoenix Contact
LS 64/4 E-L.51 50110456 Leuze Electronic
K9194XA Yokogawa
ZR01A01-05 Yokogawa
EJA110A-EVS4B-35DD/D4 Yokogawa
EJA110A-EMS4B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.27/KN22 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.29 Yokogawa
EJA110A-EMS5B-97NA/KU2/D4+990.29/KN 2.2 Yokogawa
EJA110A-EHS4B-97NA/KU2/D4 Yokogawa
EJA530A-ECS4N-09NF/KU2/C3/M15/T07/N4/D4/Z Yokogawa
EJA110A-EMS4B-97NA/KU2/N5/D4+990.26 Yokogawa
EJA110A-EMS4B-29DD/D4 Yokogawa
EJA220A-EHWA14F4A-99NN/KU2/M14/N4 Yokogawa
EJA530A-EBS4N-09NF/KU2/C3/M15/T06/N4/D4/Z+990.26 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+990.28/KN22 Yokogawa
EJA110A-EMS5B-97NA/KU2/N5+2X990.28/KN 22/102/ 103 Yokogawa
AFV30D-A41252 Yokogawa
SNB10D-425/CU2N Yokogawa
RAMC01-D4SS-61L1-J90424/A13/A16/A26/VE Yokogawa
1 KG 75 B
NORMAL OPEN BREAK
CYLINDER RATED PRESSURE 6.3 MPa. STROKE 18MM RATED PUSH 75Kn CENTRE DISTANCE 330MM ADJSTABLE SIZE 40MM
2 REPAIRE KIT OF KG-75B
NORMA OPEN BREAK CYLINDER
3 JC093.04.00- WATER INLET AIR GUIDE FAUCET
1 TYPE: LC1D475
CONTACTOR, 3P, TYPE: LC1D475, VOLTAGE: 380/400 VAC, CURRENT: 475 A, F: 50/60 HZ, COIL: 220 VAC, ITH: 700A, UI: 1000V ,SERI NO: 400 810 1315, GB/T 14048.4, IEC60947-4-1
2 TYPE: OT800E03P,3P-800A
SWITCH-DISCONNECTOR, TYPE: OT800E03P, 3P, PRODUCT ID: 1SCA022718R9410, VOLTAGE: 380-415 VAC, RATED CURRENT: 800 A, UIMP: 12 KV, ICU: 50 KA, F: 50/60 HZ, RATED INSULATION VOLTAGE: 1000 V, DIMENSIONS: 266*250*140 MM
3 TYPE:VD4/Z 12.06.32PT
VACUUM CIRCUIT BREAKER MODEL:VD4/Z 12.06.32PT,ORDER NUMDER:501205261/1001/001,SERIAL NUMBER:1YHP000040A8174,RATED VOLTAGE:12KV,RATED NORMAL CURRENT:630A,RATED ,LIGHTNING IMPULSE
4 P-400VAC-780A
CONTACTOR, TYPE: BEC1-780/22, 3 POLE, VOLTAGE: 400 VAC, CURRENT: 780 A, IEC60947-4-1, GB-140-48-4
5 TYPE:BEG1-1600,3P-1600A
SWITCH DISCONNECTOR, TYPE: BEG1-1600, 3P, VOLTAGE: 400 VAC, CURRENT: 1600 A, UE: 690 V, AC-23B, GB14048.3
6 TYPE:BE1-800 ,3P-800A
SWITCH DISCONNECTOR, TYPE: BE1-800, 3P, VOLTAGE: 400 V, CURRENT: 800 A, UI: 690 V, ICU: 50 KA, ICS: 37.5 KA , F: 50/60 HZ, IEC60947-2, GB14048.2
10 4042194 RECEPTACLE, DC POWER, DOUBLE HOLE, W/ BRASS NUT AND PROTECTIVE CAP, SECURE MOUNTSERIES, ORANGE COLOUR, FOR TOP DRIVE, MAKE: RIG POWER, P/N: SM-R2-N-OR
20 4042195 RECEPTACLE, DC POWER, DOUBLE HOLE, W/ BRASS NUT AND PROTECTIVE CAP, SECURE MOUNTSERIES, RED COLOUR, FOR TOP DRIVE, MAKE: RIG POWER, P/N: SM-R2-N-R
30 4042196 RECEPTACLE, DC POWER, DOUBLE HOLE, W/ BRASS NUT AND PROTECTIVE CAP, SECURE MOUNTSERIES, YELLOW COLOUR, FOR TOP DRIVE, MAKE: RIG POWER, P/N: SM-R2-N-Y
40 4042198 PLUG, DC POWER, SECURE MOUNT SERIES, FOR CABLE 646 MCM- COMPLETE SET WITH RUBBER BOOT, BLUE COLOR, FOR TOP DRIVE, MAKE: RIG POWER, P/N: SM-SBA-6-BL
50 4042201 PLUG, DC POWER, SECURE MOUNT SERIES, FOR CABLE 646 MCM- COMPLETE SET WITH RUBBER BOOT, RED COLOR, FOR TOP DRIVE, MAKE: RIG POWER, P/N: SM-SBA-6-R
IS2-EF8050
IS2-ЕF6060
IS2-EF8060
IS2-EF4060
IS2-EF4050
IS2-ЕF6050
ACS880-01-09A4-3+B056+E200+K475+P904+X IP55 UL Type 12I
2CDS253001R0061
1SVR040010R0000
ACS880-304-0820A-7+A018+C183
ACS880-304-0820A-7+A018+C183
ACS88001206A3
ACS880-1-206A-3+D150+K454+L508
V18345-20104610010
2500/6/0.69
AMI 500LBL VAFH
1SVR730885R3300
1SVR730774R3300
1SDA056192R5
3BDS005799R1
1SVR427065R0000
3AUA0000151852
1SBL371001R8000
FRACARRO RADIOINDUSTRIE SPA,SIG7282S,        MODULATOR, BG STEREO, AUDIO VIDEO MODULATOR, INPUT 3 X RCA, OUTPUT LEVEL: 95DB¿V
1 Contactor ABB AF 116-30-00-13 (1SFL427001R1300) 160A 100-250V
2 Contactor AF 305-30-11-13 ABB
3 The ABB RTAC-01 module
4 I/O module ABB CM RB11C
5 I/O module ABB CM RB11C
6 Interface module ABB CINT-01C
7 Interface module ABB CINT-01C
8 Interface module ABB MCB-11 C
9 Temperature measurement board TM-01C ABB 68909058 for inverters ACS800-104
10 ABB AINT-14C interface board
11 ABB AINT-14C interface board
12 ABB APOW-01C Power Supply board
13 ABB APOW-11C Power Supply board
14 AFN-02C ABB 3AXD50000038423 Engine Control board
VALVE, BALL; REFRIGERANT, 1-1/8 IN CONNECTION, ISOLATION, 40 BAR, 700 PSIG, 0637
Beam trolley integrated with Chain block 12,000 KG Hight of lift- 6 MTRS Location-E14108234/A49347
1EA X MAGNET PUMP MOD. MX -251CV5E, MFG: IWAKI, PN- IF20539D
Regulator: Gas Cylinder High Pressure 0-4 Bar, 12Kg/Hr, Mfg: Foker, F/ Propane Cylinder Mfr Part Number : B07V1N5V2D
Model number is as in my original message: Filter 2-07C-154-001 TS33753 SS .12 MID-1FSD
01 Flood Light (30 W) ''30-Watt LED Flood Light
Wattage: 30W, Voltage: 220-240V AC, Line Frequency: 50Hz, Colour: White, Shape: Square, Material: Glass, Number of Light:1, IP: 65,66,67, Best Quality
Brand: Super Star/ Walton or equivalent''
02 LED Panel Light (4 W) ''FSL T5 4W LED TUBE SET
Type: WTP-LED4 or Equivalent
Lumen Output : 300LM
Beam Angle Optional : 120°
Input Voltage : 180-265V
Power Factor : 0.6
CCT : 6500K
CRI : ≥70
IP Rating : IP20
Working Life : 25,000 Hours
Dimension (mm) : 308 x 23 x 34mm''
03 Clamp on Meter (Fluke 376) ''Fluke 376 True RMS AC/DC Clamp Meter with iFlex® or Equivalent
AC Current via Jaw: Range 999.9 A
Resolution: 0.1 A
Accuracy: 2% ± 5 digits (10-100 Hz), 2.5% ± 5 digits (100-500 Hz)
AC Current via Flexible Current Probe:Range 2500 A
DC Current:Range 999.9 A, Resolution: 0.1 A, Accuracy: 2% ± 5 digits
AC Voltage:Range 1000 V
DC Voltage:Range 1000 V
mV dc: Range 500.0 mV
Frequency via Jaw: Range 5.0 - 500.0 Hz
Frequency via Flexible Current Probe: Range 5.0 - 500.0 Hz
Resistance: Range 60 kΩ
Capacitance: Range 1000 μF
Size (L x W x H) 246 mm x 83 m x 43 mm
1000V Measurement Category (CAT) III
Batteries 2 AA, NEDA 15A, IEC LR6''
04 Surge Arresters ''Polymer Housed Metal-oxide Surge Arresters
Type: YH10W-30/102 or Equivalent
Ures: 102KV
Uc: 24KV
Udc1mA:≥42.5KV
In: 10KV
Ur: 30KV
Use in 33KV Panel''
05 SF6 gas density Digital Monitor ''SGE- HD4 Series SF6 gas density digital detecting system
Leakage rate: ≤1x10-8mbar./s (helium gas test)
Anti-vibration: 20m/s2 Impact resistance : 500m/s2
Measuring range: Density: -0.1 ~ 0.9MPa
Dew point: -80°C~+20°C
Accuracy: Density level: 1 (at20 ° C) When the ambient temperature is between 40 ° C and +60 ° C, the accuracy level is 2.5; the dew point is ± 3 ° C.
Working environment: Temperature -40 ° C ~ + 60 ° C, Relative temperature ≤ 95% RH
Installation method: Panel fixed, Punch 43mmx90mm
Protection Level: IP55
Insulation:
Insulation resistance: > 100MΩ (500V DC)
Insulation with stand voltage: 2000V, 50/60 Hz 1 min
Working voltage: DC24V
Power consumption: < 2W
Communication method: RS485
Communication protocol: MODBUS
Transmission speed: ≥ 9600bps
Anti-electromagnetic interference:
IEC61000-4-2: Level 4 (15KV)
IEC61000-4-3: Level 3 (10V/m)
IEC61000-4-4: Level 4 (4KV)
IECG1000-4-5: Level 3 (±2KV)
IEC61000-4-6: Level 3 (10V)
IECG1000-4-8: Level 4 (100A/m)
Use in 33KV Panel''
06 Emergency LED Light ''EMERGENCY LED FOG LAMP
Type: M1006 or Equivalent
Light: 2×5W LED
Emergency Time: 5 Hours
AC 220-240V 50/60Hz''
07 Indoor Cable (3x1.5 RM) ''Type : BYM (100m/ Coil)
Colour of Sheath: Black
BRB Cable or Equivalent
Standard: BDS-900, BS-6004 , IEC 60227
Voltage: 300 /500 V
Conductor : Copper ; Insulation: PVC
Inner Covering : PVC ; Sheath: PVC
Nominal Cross Sectional Area of Conductor (no x mm2): 3x 1.5 rm
No. And Nominal Diameter of wires(No/mm): 7/0.52
Max. DC Resistance at 20°C (ohm/ km) : 12.1
Nominal Thickness of Insulation (mm): 0.7
Nominal Thickness of Sheath (mm): 1.2
Approx. of Weight of Cable (kg/km): 160
Current Rating (Enclosed in Conduit/ Open Surface) at 35 °C : 15/16 A''
08 Indoor Cable (3x 2.5 RM) ''Type : BYM (100m/ Coil)
Colour of Sheath: Black
BRB Cable or Equivalent
Standard: BDS-900, BS-6004 , IEC 60227
Voltage: 300 /500 V
Conductor : Copper ; Insulation: PVC
Inner Covering : PVC ; Sheath: PVC
Nominal Cross Sectional Area of Conductor (no x mm2): 3x 2.5 rm
No. And Nominal Diameter of wires(No/mm): 7/0.67
Max. DC Resistance at 20°C (ohm/ km) : 7.41
Nominal Thickness of Insulation (mm): 0.8
Nominal Thickness of Sheath (mm): 1.2
Approx. of Weight of Cable (kg/km): 245
Current Rating (Enclosed in Conduit/ Open Surface) at 35 °C : 20/22 A''
09 Indoor Cable (5x 4 RM) ''Type : BYM (100m/ Coil)
Colour of Sheath: Black
BRB Cable or Equivalent
Standard: BDS-900, BS-6004 , IEC 60227
Voltage: 300 /500 V
Conductor : Copper ; Insulation: PVC
Inner Covering : PVC ; Sheath: PVC
Nominal Cross Sectional Area of Conductor (no x mm2): 3x 4 rm
No. And Nominal Diameter of wires(No/mm): 7/0.85
Max. DC Resistance at 20°C (ohm/ km) : 4.61
Nominal Thickness of Insulation (mm): 0.8
Nominal Thickness of Sheath (mm): 1.2
Approx. of Weight of Cable (kg/km): 310
Current Rating (Enclosed in Conduit/ Open Surface) at 35 °C : 27/30 A''
10 MCB 10A, 2 Pole ''Type: NDB2Z-63 or Equivalent
In: 10A
Voltage: 500V DC
Use in Box Transformer Panel''
11 MCB 16A, 2 Pole ''Type: NDB2Z-63 or Equivalent
In: 16A
Voltage: 500V DC
Use in Box Transformer Panel''
12 MCB 25A, 2 Pole ''25A, 2 Pole
Type: C, 220 VAC
Manufacturer: Siemens/Schneider or Equivalent''
13 MCB 32A, 2 Pole ''Type: NDB2Z-63 or Equivalent
In: 32A
Voltage: 500V DC
Use in Box Transformer Panel''
14 MCB 32A, 3 Pole ''32A, 3 Pole
Type: C, 220 VAC
Manufacturer: Siemens/Schneider or Equivalent''
15 MCB 63A, 3 Pole ''63A, 3 Pole
Type: C, 220 VAC
Manufacturer: Siemens/Schneider or Equivalent''
16 Moulded Case Circuit Breaker (100A 3P) ''Catalog Description:XT1S 160 TMD 100-1000 3p F F
Product ID:1SDA067434R1; Number of Poles:3
Power Loss:at Rated Operating Conditions per Pole 7 W
Product Main Type:S ACE Tmax XT
Product Name: Moulded Case Circuit Breaker
Product Type: CB
Rated Current (In): 100 A
Rated Frequency (f): 50 / 60 Hz; Rated Voltage (Ur): 690 V
Rated Impulse Withstand Voltage (Uimp):8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii): 1000 A
Rated Insulation Voltage (Ui): 800 V
Rated Operational Voltage:690 V AC, 500 V DC
Rated Uninterrupted Current (Iu):160 A; Setting Range:70...100 A
Rated Service Short-Circuit Breaking Capacity (Ics): (220 V AC) 63.75 kA
Product Net Width:76.2 mm; Product Net Height:130 mm; Product Net Depth / Length:70 mm; Product Net Weight:1.112 kg''
17 Battery (12V, 100Ah) ''Type: Leoch DJM12100(H) 12V 100Ah Sealed Lead Acid or Equivalent
Nominal Voltage: 12V
Nominal Capacity: 100Ah
Terminal Type: Insert Terminals - (M8 - Hardware included)
Weight: 64.9 Lbs
Length: 13'''' (330 mm)
Width: 6.73'''' (171 mm)
Height: 8.46'''' (215 mm)
Height Over Terminal: 8.66'''' (220 mm)
Use in UPS System''
18 Cabinet Cooling Fan ''G20060HA2BL 220V 65W 200×200×60mm Double Ball axial Fan
Type: G20060HA2BL or Equivalent
Size:200×200×60mm
Voltage: 220V
Current:0.48A
Power: 65W
Use in Box Transformer Panel''
19 Temperature and Humidity Controller ''Type: LD-H37B11-Q(A) or Equivalent
Power Supply: 220V AC
Fujian Lead Automation Equipment Co., Ltd.
Use in Box Transformer Panel''
20 Temperature Display Meter ''Temperature Display Meter for Transformer
Type: YE
Grade: 1.0
Range: 0.0~150°C
measurement accuracy: accuracy level 1
Resolution 0.1 ℃
service conditions: ambient temperature - 20~ + 55 ℃
Relative humidity < 95% (25 ℃)
Power supply voltage AC220V (+ 10%, - 15%)
Power frequency 50Hz or 60Hz (± 2Hz)
power consumption of thermograph: ≤ 5W
overall dimension of thermograph: 160mm × 80mm × 140mm (width) × high × (deep)
Opening size: 152 + 1mm × 76 + 1mm (width) × High)
Fujian Lead Automation Equipment Co., Ltd.
Use in Box Transformer Panel''
21 Surge Protective Device ''Type: HS-GA750/200 or Equivalent
Uc: 750V~
In: 100KA (8/20us)
Imax: 200KA (8/20us)
Up: 2.5KV
Use in Box Transformer Panel''
22 Relay ''Type: JTX-3C or Equivalent
Contact: 220VAC 7.5A, 24VDC 10A
Power Supply: 220V DC, 0.3A
Use in 33KV Switchgear Panel''
23 Temperature and Humidity Controller (3W) ''Type: HWS-2MYJ/C1 or Equivalent
Working voltage: 220VAC±10%.
Sensor line length: 3 meters.
Power consumption: less than 3W.
Contact performance: can connect 5A, can disconnect 250VAC, 250VA AC load.
Use in Switchgear Cabinet''
24 Fuse (100 A) ''Type: NT00 or Equivalent
Current: 100A
AC 690V 50KA ''
25 Fuse Annunciator ''Type: RX1-1000 or Equivalent
Voltage: AC 1000V''
26 Combiner box Monitoring Controller ''Type: FR-DCMG-MMPF or Equivalent
1. LCD screen + bar graph display, understand the power generation status of all channels at a glance
2. Support DC1000V system
3. Built-in power supply, photovoltaic self-power supply
4. Alarm for abnormal string status (overvoltage, undervoltage, overcurrent, undercurrent, unbalanced current, etc.) 5. Remote communication method RS485 MODBUS-RTU, industrial wireless
6. Local alarm display, you can check the channels generating harmful arcs at any time
7. One external temperature detection, two switch input detection
Use in Combiner box''
27 Hall Current Sensor ''Type: FR-DCMG-HS4A or Equivalent
Current Range: 20A
Channel: 4
Use in Combiner box''
28 String Fuse Base ''Type:SLFC SLPV-30DN or equivalent
Current: 30 A
Voltage: 1000V DC
Use in Combiner box''
29 String Fuse (15 A) ''Type: SLFC SLPV-30 or equivalent
Current: 15A
Voltage: 1000V DC
Use in Combiner box''
30 Mc4 Connector ''Material Plastic
Connector Type MC4
Maximum Voltage 1500 Volts
High Quality MC4 Connector
Male-Female Pair
25 Year Life
Contact material: copper, tin plated
IP67 Protection
Use in Solar Field to Connect Each other''
31 Lighting Protector ''Photovoltaic Confluence Lighting Protection
Type: ERT40-T2-1000-S-PV or Equivalent
Uc: 1300V
Upv: 1000V
Up: 4KV
Imax: 40KA
In: 20KA
Use in Combiner Box''
32 Frequency Transducer ''Type: GPF-F1-P2-03/B3 or Equivalent
Input: 48 ~ 52Hz
Output: 4 ~ 20mA DC
Class: 0.5
Power AC 220V
Use in UPS Panel''
33 Voltage Transducer ''Type: GPV-V2-F1-P2-03 or Equivalent
Input: 0 ~ 300V 50Hz
Output: 4 ~ 20mA DC
Class: 0.5
Power AC 220V
Use in UPS Panel''
34 Current Transducer ''Type: GPA-A2-F1-P2-03 or Equivalent
Input: 0 ~ 5A 50Hz
Output: 4 ~ 20mA DC
Class: 0.5
Power AC 220V
Use in UPS Panel''
35 Current Transformer (600/5A) ''Type: LMK-0.66 or Equivalent
Ratio: 600/5A
Accuracy: 0.5
Frequency: 50-60Hz
Burder: 10VA-3.75VA
Voltage: 0.66/3/-KV''
36 Silica Gel ''Classification : Chemical Auxiliary Agent
Other Names : silica desiccant
Purity : 99% ; Type : Adsorbent
Adsorbent Variety : Silica Gel
Size : 5mm ; Color : Blue
Shape : Bead & lump
Pore volume :: 0.35-0.45ml/g''
37 Electrical Rubber Mat ''Type: RC04153-CL0-BLK or Equivalent
Material: Rubber elastomer
Roll length: 10m
Roll width: 1m
Thickness 3mm
Maximum tested voltage: 10,000V
Safe working voltage: 1000V
Colour code: Red
Weight: 3.5kg (per metre)
Colour: Black''
38 Magnetic Contacts (25A) ''
Type: AX25-30-11-80 or equivalent
AC-3 Current : 25A
Coil Voltage : 220-230V
Auxiliary contact: 1 NO + 1 NC
Rated frequency: 50/60 Hz
Mounting: DIN rail
ABB or equivalent
Use in Air conditioner''
39 Air Conditioner Blower Fan Motor ''Fan Motor for room air conditioner
Type: YDK65-6F(B) (YKT-65-6-34L) or Equivalent
Voltage: 220-240V AC
Frequency: 50Hz
Power: 65W
Pole: 6
Rated Current: 0.8A
Insulation Class: B
LRA: 1.1A''
40 Air Conditioner Outdoor Card ''Type: SA-KFR140W/S2-590.ZY001.JD.FW.WXWKD.WP1-1 or Equivalent
4 Ton Media AC Outdoor Card''
41 Air Conditioner Compressor (48000 Btu, R410A) ''Cooling Capacity: 48000 Btu/h
Type: Hermetically sealed Rotary Compressor
Refrigerant: R410A
Phase: 3 Phase
Voltage: 415VAC
Brand: Toshiba/Panasonic/Hitachi/LG/Gree or equivalent''
42 Soft Starter ''Type: Schneider ATS22D17Q or Equivalent
Range of product: Altistart 22
Product or component type: Soft starter
Product destination: Asynchronous motors
Product specific application: Pumps and fans
Component name: ATS22
Network number of phases: 3 phases
[Us] rated supply voltage: 230...440 V - 15...10 %
Motor power kW:
4 kW 230 V
7.5 kW 400 V
7.5 kW 440 V
Factory setting current: 14.8 A
Power dissipation in W: 39 W for standard applications
Utilisation category: AC-53A
Size: H × W × D= 265 × 130 × 169 mm
IP degree of protection: IP20
Use in Solar pressure Pump''
43 Photovoltaic Fuse ''Type: S3L gPV 350A/1100V DC UL or Equivalent
ETI Code: 004110481
Class name: Fuse link
Type: NH-S
Size: 3L
Rated current (A): 350
Rated DC voltage (V): 1100
Characteristics: gPV
L/R (ms): 2
Breaking capacity DC (kA): 10
Application:
Fuse-link for DC application
Dimensions: S170mm
Indicator: Top fuse status indicator
Power dissipation (W): 58
Power dissipation (0,7x In) (W): 26
Operating joule integral (A2s): 260.000
Prearcing joule integral (A2s): 195.000
Standards: IEC 60269-6, UL 248-19
UL certificate: E347771''
1 Feedrate 7~75
2 Feeder Inlet Diameter 629
3 Center Distance Between Inlet And Discharge 2200
4 Belt Drive 3
5 Cleanout Conveyor Motor Power 0.37
6 Feeder Over Dimensions (L×W×H) 3425×1700×1710
7 Weight Of Feeder 3.5
TYPE:LOGIC CONTROLLER
MEMORY:128 MB
DIGITAL INPUT: 16
DIGITAL OUTPUT: 12
ANALOG INPUT: 8
ANALOG OUTPUT: 4
POWER SUPPLY INPUT: 24 VDC MAKE:MOOG
MODEL/MLFB/TYPE NUMBER:MC600
REDUNDANCY: REQUIRED
COMMINICATION TYPE: ETHERNET
PROGRAMMING LANGUAGE: FBD
1 HYDRAULIC MOTOR;151 V 3003;OMP-315;DANFOSS;BLENDER MS-60;315sm3,G3/4,GEROTOR,BLENDER MIXER
2 CONVEYOR BELT;UNIBET-1800 CONVEYOR;WITH CORRUGATORS,36" inch,102'-3" inch,PVC
3 PUMP;FMT 23337;PRESSOL;GEAR,1/2"inch,3/4" inch,ELECTRIC, 220V, 1.8kW,OIL PUMPING
4 STRUCTURAL PLATE;###-XXX-611-01;BLENDER MS-60;STEEL,SUPPORT,BLENDER VAT
5 PUMP REPAIR KIT;519274;DANFOSS; CYLINDER BLOCK KIT, DANFOSS 90L130GBA PUMP
6 SEAL;1546-KB20S30;WANGEN;WANGEN KB20S 30 PUMP
1 "230 KV Isolator Auxiliary Contact Block
Type: HS 7K.01
E-Nr: 910-304-551-00
Ith: 10 Amp
Torque: 0.8 N-m
Manufacturer: AEG, Germany"
2 "230 KV Isolator Magnetothermic Circuit
Breaker
Type:MBS 25
E-Nr: 910-201-207
25 A, AC3, 8 KV/3
Thermal Signal: 2.5-4 A
Overcurrent signal: 40 A
Manufacturer: AEG, Germany"
3 "230 KV Isolator Opening /Closing
Contactor
Type: LS 5K
Coil Voltage: 220 VDC, LB1DN, C660-19
Ith: 25A, Ui: 1000 V, Auxiliary Contact Ith:
16 A,
torque: 1.6 N.m,
Manufacturer: AEG, Germany"
4 "230 KV Isolator Electromagnetic
Interlocking Device
Model:E 204 SF 220 VDC 10%
M.A.G., CARONNO PERTUSELLA
Manufacturer: M.A.G."
5 "230 KV Isolator Opening/Closing Push
Button Switch
(contact Block + push button)
Contact Block:P9B11VN
Type: SES 10, 1 NO+1NC
Ith: 10 A, Uimp: 4 KV
With Black push button: P9MPNNG
Manufacturer: GE, CEMA, Made in Italy."
6 "230 KV Isolator Limit Switch with roller
type actuator
Switch Part No:EF83161.3
10(4)A 400 VAC, 16(4) 250 VAC, T125
Actuator Part Number: 79215742
Roller 161E R13.6
Manufacturer: Crouzet"
7 "Switchyard marshalling kiosk Terminal
Block
Model: DATN 35A
Accessory includes:
Separator: DAAN 35
Name Plate: DTNN 1.2
Cover: DACN 1(38x500 mm)
Make: DONG-A BESTECH"
1.            CONTACTOR;CONTACT ARRANGEMENT:1 NO - 2 NC, COILVOLTAGE:110
120 VAC VAC, ELECTRICAL POLE QUANTITY:3,MAXIMUM
CURRENT RATING:50 A, ENCLOSURE RATING:63A;
REFERENCE NO: X13070432030,FFT: P/N: XMCO-503-FBBC3RFZ;
MNFR: HONGMEI ELECT.CO.LTD.; FREQUENCY: 50/60 HZ;HOMMER SERIES
 
2.             CONTACTOR; COIL VOLTAGE:110-120 VAC, ELECTRICAL POLE
QUANTITY:3, MAXIMUM CURRENT RATING:25 A,ENCLOSURE
RATING:63; SERIAL NO: X13070073010, FFT: P/N: XMCO-253-FBBC00F
MNFR: HONGMEI ELECT.CO.LTD.; FREQUENCY: 50/60 HZ;HOMMER SERIES
EX TYPE BALLAST 36W--P/N:CEB08218-36, COPPER
P NO:CEB08218-36
BALLAST FOR 2 X 36W FLUORESCENT LIGHTING, COOPER OR EQUIVALENT
1 Breaker, Circuit, 5 AF, 5 AT 480V 2 pole Din Rail
2 24 Volt DC Coil Molded Type Series 20, 80 Coils
3 Power Service Loop, 86 Foot Long, 3 X 646 MCM cables (individually tinned copper braided) plus 3 X 2/0 AWG Cables (Ground), Cable Tails to be minimum 7 Metres Long at Derrick Junction Box end and minimum 5 metres long at Top Drive Junction Box end.
4 646 kcmil Two-Hole Lug Compression Connector, Straight Barrel, 12mm Holes.
5 646 kcmil One-Hole Lug Compression Connector, Straight Barrel, 22mm Hole.
6 2/0 AWG One-Hole Lug Compression Connector, Straight Barrel, 12mm Hole.
7 Control Composite Service Loop
8 AUX Power Composite Service Loop
9 Solenoid Valve Assy, Cenelec, 24 volt-DC, Air operated
10 ENCODER, DIGITAL INCREMENTAL, ST.ST., IP66, II 2GD, EEx d IIC T6, Ta -20oC to +60oC & I M2, EEx d I Ta -20oC to +60oC. Manufacturer: HOHNER AUTOMATION, P/N HSP1014.
11 BELT, TIMING
12 Solenoid Valve 4/2, 24Vdc Eexd, (MFG# ATOS, Part# 000290-DHA-0631/2/M/7-24VDC)
13 Power Service Loop, 86 Foot Long, 3 X 646 MCM cables (individually tinned copper braided) plus 3 X 2/0 AWG Cables (Ground), Cable Tails to be minimum 7 Metres Long at Derrick Junction Box end and minimum 5 metres long at Top Drive Junction Box end.
14 Solenoid Valve, 24Vdc Eexd, (MFG# VERSA PRODUCTS , Part# VGG-4532-MS-XDAS-167-D024 C)
15 Proportional Solenoid Valve, 24Vdc Eexd, (MFG# ATOS, Part# DHRZA-P5-012/25-M)
16 Lube Oil Pressure Switch, (MFG# PYROPRESS, Part# PF261S1B/2B10F32B/67S6AA)
17 Differential Pressure Switch, (MFG# PYROPRESS, Part# DPF266S1B/BGF08SB1/WA)
18 Differential Pressure Switch, (MFG# PYROPRESS, Part# DPF266S1B/BPF01SB2/AA)
19 Linear Transducer, (MFG# SUMMIT ELECTRIC, Part# HPH-11-01-0800-0510-A)
20 Over Temperature Switch, (MFG# PYROPRESS, Part# DPF266S1B/BGF08SB1/WA)
21 Over Temperature Switch, (MFG# BROOK MOTORS, Part# A-EF160LZ)
22 Proximity Sensor, (MFG# PEPPERL & FUCHS, Part# TF176S1B/43316)
23 Flow Switch, 25 GPM (MFG# MALEMA, Part# M-200X-S43-013)
24 Flow Switch, 1.2 GPM (MFG# MALEMA, Part# M-200X-S43-014)
25 Switch Pressure, 24VDC, Hydraulic input, Explosion proof, for NOV,TDS, RLA.
26 Power Service Loop, 86 Foot Long, 3 X 646 MCM cables (individually tinned copper braided) plus 3 X 2/0 AWG Cables (Ground), Cable Tails to be minimum 7 Metres Long at Derrick Junction Box end and minimum 5 metres long at Top Drive Junction Box end.
27 Module, Resistor Complete, 433KW, 1120 V DC2
28 Lube Oil Pump AC Motor NDE Bearing
29 Lube Oil Pump AC Motor DE Bearing
30 Blower AC Motor NDE Bearing
31 Blower AC Motor DE Bearing
32 Main/Drilling AC Motor NDE Bearing
33 Main/Drilling AC Motor DE Bearing
BRADLEY CORP S24-188 SHOWERHEAD;PLASTIC ASSEMBLY
BRADLEY CORP S24-187 ASSY;FLOW CONTROL,23GPM
BRADLEY CORP 124-028 GASKET;CENTER SEAL
BRADLEY CORP 154-058 BOWL;PLASTIC EYEWASH
BRADLEY CORP 173-025 STRAINER;CUP ABS EFX
BRADLEY CORP S21-071 ASSY;SUPPLY STEM W/FLOW CONTROL REPLACEMENT
BRADLEY CORP 113-1185 SPACER;DRAIN EYEWASH

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
Business time
9:00-22:00
  • Email:support@rig123.com