YH DZF-005
Maximum working voltage: DC 1200V
Resistance (20 ° C): 4X4.45 ± 5%
Rated power: 200 X 4KW
Cooling method: forced air cooling (2 fans, AC380V)
Working mode: 20s (working) + 70s (stop)
Dimensions: 2168 (L) X 1098 (W) X 665 (H)
YH DZF-006
Maximum working voltage: DC 1200V
Resistance (20 ° C): 9 ~ 15X4.45 ± 5%
Rated power: 200 X 13KW
Cooling method: forced air cooling (4 fans, AC380V)
Working mode: 20s (working) + 70s (stop)
Dimensions: 2444 (L) X 1183 (W) X 1182 (H)
YH DZF-007
Working voltage: 890 ~ 1158V
Resistance (20 ° C): 12X4.45 ± 5%
Rated power: 200 X 12KW
Cooling method: forced air cooling (4 fans, AC380V)
Use environment: outdoor type, must be rainproof
Dimensions: 2444 (L) X 1208 (W) X 1680 (H)
YH DZF-008
Working voltage: 510 ~ 620V
Resistance (20 ° C): 2.35 ± 5%
Rated power: 170KW
Cooling method: forced air cooling (1 fan, AC380V)
Working mode: 20s (working) + 70s (stop)
Dimensions: 1284(L)X 649(W)X 665(H)