LC1D098M7
1
  •  LC1D098M7
2
views: 418

LC1D098M7

Rate:
0.0000/5

( 0 reviews )

Item NO.: V030358 MOQ: 0
Weight:    0.5kgs
Package Size:  
 Price:
$190.00
 Qty:
      $190.00
 Shipping:   Calculate Shipping Cost

 ZLL(YL)

LC1D098M7

delivery time:in stock



Main
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
AC-3
AC-3e
AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 250 V DC
[Ie] rated operational current 20 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 2 NO + 2 NC
Contact compatibility M6
Protective cover With
[Ith] conventional free air thermal current 20 A 140 °F (60 °C) power circuit
10 A 140 °F (60 °C) signalling circuit
Irms rated making capacity 250 A 440 V power circuit IEC 60947
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
Rated breaking capacity 250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit
210 A 104 °F (40 °C) - 1 s power circuit
30 A 104 °F (40 °C) - 10 min power circuit
61 A 104 °F (40 °C) - 1 min power circuit
100 A - 1 s signalling circuit
120 A - 500 ms signalling circuit
140 A - 100 ms signalling circuit
Associated fuse rating 10 A gG signalling circuit IEC 60947-5-1
25 A gG <= 690 V type 1 power circuit
20 A gG <= 690 V type 2 power circuit
Average impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit
Power dissipation per pole 1.56 W AC-1
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 0.3 Mcycles 20 A AC-1 <= 690 V
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc -40…140 °F (-40…60 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz
Inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C))
70 VA 50 Hz 0.75 68 °F (20 °C))
Hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C))
7 VA 50 Hz 0.3 68 °F (20 °C))
Heat dissipation 2…3 W 50/60 Hz
Operating time 12...22 ms closing
4...19 ms opening
Maximum operating rate 3600 cyc/h 140 °F (60 °C)

 
No comment