Product characteristics
|
Laser protection class
|
2
|
Housing
|
rectangular
|
Electrical data
|
Operating voltage [V]
|
18...30 DC; (operating voltage "supply class 2" according to cULus)
|
Current consumption [mA]
|
< 150
|
Protection class
|
III
|
Reverse polarity protection
|
yes
|
Typ. lifetime [h]
|
50000
|
Inputs / outputs
|
Number of inputs and outputs
|
Number of digital outputs: 2; Number of analogue outputs: 1
|
Outputs
|
Total number of outputs
|
2
|
Electrical design
|
PNP
|
Number of digital outputs
|
2
|
Output function
|
normally open / normally closed; (parameterisable)
|
Max. current load per output [mA]
|
200
|
Number of analogue outputs
|
1
|
Analogue current output [mA]
|
4...20; (IEC 61131-2)
|
Max. load [Ω]
|
250
|
Analogue voltage output [V]
|
0...10; (IEC 61131-2)
|
Min. load resistance [Ω]
|
5000
|
Short-circuit protection
|
yes
|
Type of short-circuit protection
|
pulsed
|
Overload protection
|
yes
|
Detection zone
|
Max. light spot width [mm]
|
15
|
Max. light spot height [mm]
|
15
|
Light spot dimensions refer to
|
10 m
|
Background suppression [m]
|
0...19
|
Measuring/setting range
|
Measuring range [m]
|
0.2...10; (white paper 200 x 200 mm 90% remission)
|
Sampling rate [Hz]
|
1...50
|
Interfaces
|
Communication interface
|
IO-Link
|
Transmission type
|
COM2 (38,4 kBaud)
|
IO-Link revision
|
1.1
|
SDCI standard
|
IEC 61131-9
|
Profiles
|
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
|
SIO mode
|
yes
|
Required master port type
|
A
|
Process data analogue
|
2
|
Process data binary
|
3
|
Min. process cycle time [ms]
|
6
|
Supported DeviceIDs
|
Type of operation
|
DeviceID
|
Default
|
806
|
|
Operating conditions
|
Ambient temperature [°C]
|
-10...60
|
Protection
|
IP 67
|
Tests / approvals
|
EMC
|
|
Laser protection class
|
2
|
Notes on laser protection
|
Caution:
|
laser light
|
Power:
|
<= 4 mW
|
Wave length:
|
650 nm
|
pulse:
|
1,3 ns
|
Do not stare into beam.
|
|
Avoid exposure to the laser light.
|
|
laser class:
|
2
|
|
EN / IEC60825-1:2007
|
|
EN / IEC60825-1:2014
|
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
|
|
MTTF [years]
|
182
|
Mechanical data
|
Weight [g]
|
243.5
|
Housing
|
rectangular
|
Dimensions [mm]
|
59 x 42 x 52
|
Materials
|
housing: diecast zinc; front lens: glass; LED window: PC
|
Lens alignment
|
side lens
|
Displays / operating elements
|
Display
|
switching status
|
2 x LED, yellow
|
operation
|
LED, green
|
distance value, programming
|
alphanumeric display, 4-digit
|
|
Accessories
|
Accessories (optional)
|
|
Remarks
|
Remarks
|
For more information about the measuring range / application please refer to the operating instructions.
|
|
Pack quantity
|
1 pcs.
|
Electrical connection
|
Connection
|
Connector: 1 x M12; coding: A
|
Other data
|
Parameter
|
Setting range
|
Factory setting
|
Uni
|
mm, m, inch
|
mm
|
OU1
|
Hno, Hnc, Fno, Fnc
|
Hno
|
SP1 [mm]
|
200...9999
|
1000
|
nSP1 [mm]
|
200...9999
|
800
|
FSP1 [mm]
|
200...9999
|
1200
|
OU2
|
Hno, Hnc, Fno, Fnc, I, U
|
I
|
SP2 [mm]
|
200...9999
|
2000
|
nSP2 [mm]
|
200...9999
|
1800
|
FSP2 [mm]
|
200...9999
|
2200
|
ASP [mm]
|
0...9999
|
0
|
AEP [mm]
|
0...9999
|
9999
|
rATE [Hz]
|
1...50
|
50
|
dS1 [s]
|
0...0.1...5
|
0
|
dr1 [s]
|
0...0.1...5
|
0
|
dS2 [s]
|
0...0.1...5
|
0
|
dr2 [s]
|
0...0.1...5
|
0
|
dFo [s]
|
0...0.1...5
|
0
|
dIS
|
d1...3 ; rd1...3; OFF
|
d3
|
|
repeatability/accuracy
|
read/write distance (mm)
|
repeatability of the measured values
|
|
accuracy
|
|
|
white (90 % remission)
|
grey (18 % remission)
|
white (90 % remission)
|
grey (18 % remission)
|
200...1000 mm
|
± 5.0 mm
|
±7.5 mm
|
± 15.0 mm
|
± 18.0 mm
|
1000...2000 mm
|
± 5.5 mm
|
±10.0 mm
|
± 15.0 mm
|
± 20.0 mm
|
2000...4000 mm
|
± 17.5 mm
|
±22.5 mm
|
± 25.0 mm
|
± 32.0 mm
|
4000...6000 mm
|
± 27.5 mm
|
±40.0 mm
|
± 35.0 mm
|
± 50.0 mm
|
6000...10000 mm
|
± 60.0 mm
|
|
± 70.0mm
|
|
|
Sampling rate
|
50 Hz
|
Extraneous light on the object
|
< 40 klx
|
|
repeatability/accuracy
|
read/write distance (mm)
|
repeatability of the measured values
|
|
accuracy
|
|
|
white (90 % remission)
|
grey (18 % remission)
|
white (90 % remission)
|
grey (18 % remission)
|
200...1000 mm
|
± 16.5 mm
|
±16.5 mm
|
± 26.5 mm
|
± 26.5 mm
|
1000...2000 mm
|
± 16.5 mm
|
±16.5 mm
|
± 26.5 mm
|
± 26.5 mm
|
2000...4000 mm
|
± 30.0 mm
|
±37.0 mm
|
± 40.0 mm
|
± 47.0 mm
|
4000...6000 mm
|
± 37.0 mm
|
±57.0 mm
|
± 47.0 mm
|
± 67.0 mm
|
6000...10000 mm
|
± 75.0 mm
|
—
|
± 85.0mm
|
—
|
|
Sampling rate
|
50 Hz
|
Extraneous light on the object
|
40...100 klx
|
|
repeatability/accuracy
|
read/write distance (mm)
|
repeatability of the measured values
|
|
accuracy
|
|
|
white (90 % remission)
|
grey (18 % remission)
|
white (90 % remission)
|
grey (18 % remission)
|
200...1000 mm
|
± 4.0 mm
|
±4.5 mm
|
± 14.0 mm
|
± 15.0 mm
|
1000...2000 mm
|
± 4.5 mm
|
±6.0 mm
|
± 14.5 mm
|
± 16.0 mm
|
2000...4000 mm
|
± 13.5 mm
|
±14.5 mm
|
± 23.5 mm
|
± 24.0 mm
|
4000...6000 mm
|
± 19.0 mm
|
±21.0 mm
|
± 29.0 mm
|
± 31.0 mm
|
6000...10000 mm
|
± 37.0 mm
|
–
|
± 47.0mm
|
–
|
|
Sampling rate
|
1 Hz
|
Extraneous light on the object
|
< 40 klx
|
|
repeatability/accuracy
|
read/write distance (mm)
|
repeatability of the measured values
|
|
accuracy
|
|
|
white (90 % remission)
|
grey (18 % remission)
|
white (90 % remission)
|
grey (18 % remission)
|
200...1000 mm
|
± 10.0 mm
|
± 10.0 mm
|
± 20.0 mm
|
± 20.0 mm
|
1000...2000 mm
|
± 10.0 mm
|
± 10.0 mm
|
± 20.0 mm
|
± 20.0 mm
|
2000...4000 mm
|
± 17.0 mm
|
± 18.0 mm
|
± 27.0 mm
|
± 28.0 mm
|
4000...6000 mm
|
± 22.0 mm
|
± 25.0 mm
|
± 32.0 mm
|
± 35.0 mm
|
6000...10000 mm
|
± 37.0 mm
|
–
|
± 47.0mm
|
–
|
|
Sampling rate
|
1 Hz
|
Extraneous light on the object
|
< 40...100 klx
|
-
|
-
|
Range on black object (6 % remission)
|
<= 4000 mm
|
-
|
-
|
The values apply at
|
|
constant ambient conditions
|
23 °C / 960 hPa
|
minimum power-on time in minutes
|
10
|
|