NJ5-30GK-S1N
1
  • NJ5-30GK-S1N
2
views: 522

NJ5-30GK-S1N

Rate:
0.0000/5

( 0 reviews )

Item NO.: V023249 MOQ: 0
Weight:    2kgs
Package Size:  
 Price:
$108.00
 Qty:
      $108.00
 Shipping:   Calculate Shipping Cost
Manufacturer : Pepperl+Fuchs
Inductive sensor NJ5-30GK-S1N-10M
Nonferrous targets
5 mm flush in ST37 / 1.0037
Usable up to SIL 3 acc. to IEC 61508
ATEX approval Ex-i and Ex-nA/tc for zone 0-2 and zone 20-22
Degree of protection IP68
Switching function : Normally open (NO)
Output type : NAMUR with safety function
Rated operating distance : 5 mm
Installation : flush in mild steel
Assured operating distance : 0 ... 4.05 mm
Reduction factor rAl : 1
Reduction factor rCu : 1
Reduction factor r304 : 0


Safety Integrity Level (SIL) : up to SIL3 acc. to IEC 61508Danger!In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.


Nominal ratings
Nominal voltage : 8.2 V
Switching frequency : 0 ... 150 Hz
Suitable for 2:1 technology : yes , with reverse polarity protection diode
Current consumption
Measuring plate not detected :≤1 mA
Measuring plate detected : ≥3 mA
Functional safety related parameters
MTTFd : 11850 a
Mission Time (TM) : 20 a
Diagnostic Coverage (DC) : 0 %
Approvals and certificates
UL approval : cULus Listed, General Purpose
CCC approval : CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature : -25 ... 100°C (-13 ... 212°F)
Mechanical specifications
Connection type : cable silicone , 10 m
Core cross-section : 0.75 mm2
Housing material : Crastin (PBTB), black
Sensing face : Crastin (PBTB), black
Housing diameter : 30 mm
Degree of protection : IP68
Cable
Bending radius : > 10 x cable diameter
Note : only for non-ferrous metal
Equipment protection level Gc (nA)
Certificate of Compliance : PF 15CERT3754 X
: Special conditions
Protection against transients : Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
: Instruction : Manual electrical apparatus for hazardous areas
: Device category 3D : for use in hazardous areas with combustible dust
Certificate of Compliance : PF 15CERT3774 X
CE marking : [*PD-Z02586A*]
ATEX marking : II 3D Ex tc IIIC T80??C Dc
The Ex-related marking can also be printed on the enclosed label.
Standards : EN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.


General : The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.


Installation, commissioning : Laws and/or regulations and standards governing the use or intended usage goal must be observed. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion!


Maintenance : No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.


: Special conditions


Minimum series resistance RV : A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.


Maximum operating voltage UBmax : The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.


Maximum permissible ambient temperature TUmax : Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.


at UBmax=9 V, RV=562 Ω : 58°C (136.4°F)
using an amplifier in accordance with EN60947-5-6 : 331 K
Protection from mechanical danger : The sensor must not be exposed toANY FORMof mechanical danger.
Protection from UV light : The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cable : The connection cable must be prevented from being subjected to tension and torsional loading.


Electrostatic charge : Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous area : see instruction manuals
Category : 1G; 2G; 3G; 1D; 3D


 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Business time
9:00-22:00
  • Email:support@rig123.com