XCSF-500C CABUR
delivery time: in stock
Single-phase switching | |||
power supply 120-230 Vac | |||
output power 500 W | |||
• Single-phase input 120 and 230 Vac | |||
• Short circuit, overload, over temperature, input and | |||
output overvoltage protections | |||
• High outrush current to guarantee downstream overcurrent | |||
protections selectivity and to start-up heavy loads | |||
• Compact dimensions | |||
• Suitable for applications in SELV and PELV circuits | |||
• Failure contact for Uout -10% | |||
VERSIONS | Cod. XCSF500C Cod. XCSF500D | ||
Output 24 Vdc
20 A – Output 24 Vdc 20 A redundant version Output 12…15 Vdc 40 A Output 48 Vdc 10 A redundant version |
CSF500C | – | CSF500D |
INPUT TECHNICAL DATA | |||
Input rated voltage 120–230 Vac (range 90…132 Vac / 185…264 Vac) (2) | |||
Frequency 47...63 Hz | |||
Current @ nominal Iout (Uin 120 /230 Vac) 4.1 A / 2 A ± 10% | |||
Inrush peak current < 25 A with electronic limiter | |||
Power factor > 0.75 with PFC | |||
Internal protection fuse — | |||
External protection on AC line circuit breaker: 16 A C characteristic - fuse: T 15 A | |||
OUTPUT TECHNICAL DATA | |||
Output rated voltage 24 Vdc 48 Vdc | |||
Output adjustable range 24...28 Vdc 45…55 Vdc | |||
Continuous current 20 A @ 45°C (3) 10 A @ 45°C (3) | |||
Overload limit 30 A for >5 s | |||
with Uout >90% Un (4) | |||
15 A for >5 s | |||
with Uout >90% Un (4) | |||
Short circuit peak current >50 A for 5 s (4) >50 A for 5 s (4) | |||
Load regulation < 0.5% < 0.5% | |||
Ripple @ nominal ratings ≤ 50 mVpp ≤ 50 mVpp | |||
Hold up time @ In (Uin 120 / 230 Vac) >12 ms / >20 ms >12 ms / >20 ms | |||
Overload / short circuit protections hiccup at the overload limit with auto reset / over temperature protection | |||
Status display “DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED | |||
Alarm contact threshold 21.6 Vdc 43.2 Vdc | |||
Parallel connection possible possible | |||
Redundant parallel connection factory provided with internal ORing diode factory provided with internal | |||
ORing diode | |||
GENERAL TECHNICAL DATA | |||
Efficiency
(Uin 120 / 230 Vac) >92% / >92% Dissipated power (Uin 120 / 230 Vac) 42 W / 42 W |
>92% / >92% 42 W / 42 W |
||
Operating temperature range –20...+60°C, with derating over 45°C / over temperature protection (3) | |||
Input/output isolation 3 kVac / 60 s SELV output | |||
Input/ground isolation 1.5 kVac / 60 s | |||
Output/ground isolation 0.5 kVac / 60 s | |||
Standard/approvals EN50178, EN61558, EN60950, IEC950, UL508 | |||
EMC Standards EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 | |||
MTBF @ 25°C @ nominal ratings >500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F | |||
Overvoltage category/Pollution degree | |||
Protection degree IP 20 IEC 529, EN60529 | |||
Connection terminal 4 and 6 mm² fixed screw type | |||
Housing material aluminium | |||
Approx. weight 1,3 kg (45.89 oz) | |||
Mounting information vertical on rail, allow 10 mm spacing between adjacent components | |||
MOUNTING ACCESSORIES | |||
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB |