HCM(XWY)
ATV312HU30N4
Delivery time:in stock
Range of product | Altivar 312 |
---|---|
Product or component type | Variable speed drive |
Product destination | Asynchronous motors |
Product specific application | Simple machine |
Assembly style | With heat sink |
Component name | ATV312 |
Motor power kW | 3 kW |
[Us] rated supply voltage | 380...500 V - 15...10 % |
Supply frequency | 50...60 Hz - 5...5 % |
Network number of phases | 3 phases |
Line current |
10.9 A at 380 V, Isc = 5 kA 8.3 A at 500 V |
EMC filter | Integrated |
Apparent power | 7.1 kVA |
Maximum transient current | 10.7 A for 60 s |
Power dissipation in W | 125 W at nominal load |
Speed range | 1…50 |
Asynchronous motor control profile |
Sensorless flux vector control with PWM type motor control signal Factory set : constant torque |
Electrical connection |
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14 L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 5 mm² AWG 10 |
Supply |
Internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA, protection type: overload and short-circuit protection |
Communication port protocol |
CANopen Modbus |
IP degree of protection |
IP20 on upper part without cover plate IP21 on connection terminals IP31 on upper part IP41 on upper part |
Option card |
Communication card for CANopen daisy chain Communication card for DeviceNet Communication card for Fipio Communication card for Modbus TCP Communication card for Profibus DP |
Supply voltage limits | 323…550 V |
---|---|
Prospective line Isc | 5 kA |
Continuous output current | 7.1 A at 4 kHz |
Output frequency | 0…500 Hz |
Nominal switching frequency | 4 kHz |
Switching frequency | 2...16 kHz adjustable |
Transient overtorque | 170…200 % of nominal motor torque |
Braking torque |
150 % during 60 s with braking resistor 100 % with braking resistor continuously 150 % without braking resistor |
Regulation loop | Frequency PI regulator |
Motor slip compensation |
Adjustable Automatic whatever the load Suppressable |
Output voltage | <= power supply voltage |
Tightening torque |
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6: 0.6 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 1.2 N.m |
Insulation | Electrical between power and control |
Analogue input number | 3 |
Analogue input type |
AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance: 30000 Ohm AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm AI3 configurable current 0...20 mA, impedance: 250 Ohm |
Sampling duration |
AI1, AI2, AI3: 8 ms analog LI1...LI6: 4 ms discrete |
Response time |
AOV, AOC 8 ms for analog R1A, R1B, R1C, R2A, R2B 8 ms for discrete |
Linearity error | +/- 0.2 % for output |
Analogue output number | 1 |
Analogue output type |
AOC configurable current: 0...20 mA, impedance: 800 Ohm, resolution: 8 bits AOV configurable voltage: 0...10 V, impedance: 470 Ohm, resolution: 8 bits |
Discrete input logic |
Logic input not wired (LI1...LI4), < 13 V (state 1) Negative logic (source) (LI1...LI6), > 19 V (state 0) Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1) |
Discrete output number | 2 |
Discrete output type |
Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles Configurable relay logic: (R2A, R2B) NC - 100000 cycles |
Minimum switching current | R1-R2 10 mA at 5 V DC |
Maximum switching current |
R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
Discrete input number | 6 |
Discrete input type | (LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm |
Acceleration and deceleration ramps |
Linear adjustable separately from 0.1 to 999.9 s S, U or customized |
Braking to standstill | By DC injection |
Protection type |
Input phase breaks: drive Line supply overvoltage and undervoltage safety circuits: drive Line supply phase loss safety function, for three phases supply: drive Motor phase breaks: drive Overcurrent between output phases and earth (on power up only): drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: motor |
Insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
Local signalling |
1 LED (red) for drive voltage Four 7-segment display units for CANopen bus status |
Time constant | 5 ms for reference change |
Frequency resolution |
Analog input: 0.1...100 Hz Display unit: 0.1 Hz |
Connector type | 1 RJ45 for Modbus/CANopen |
Physical interface | RS485 multidrop serial link |
Transmission frame | RTU |
Transmission rate |
10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen 4800, 9600 or 19200 bps for Modbus |
Number of addresses |
1…127 for CANopen 1…247 for Modbus |
Number of drive |
127 for CANopen 31 for Modbus |
Marking | CE |
operating position | Vertical +/- 10 degree |
Outer dimension |
402 x 239 x 192 mm 184 x 140 x 150 mm 215 x 185 x 158 mm |
Height | 184 mm |
Width | 142 mm |
Depth | 152 mm |
Net weight | 3.1 kg |
Dielectric strength |
2410 V DC between earth and power terminals 3400 V AC between control and power terminals |
---|---|
Electromagnetic compatibility |
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Standards |
IEC 61800-5-1 IEC 61800-3 |
Product certifications |
DNV UL C-Tick NOM CSA GOST |
Pollution degree | 2 |
Protective treatment | TC |
Vibration resistance |
1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for storage | -25…70 °C |
Ambient air temperature for operation |
-10…50 °C without derating (with protective cover on top of the drive) -10…60 °C with derating factor (without protective cover on top of the drive) |
Operating altitude |
<= 1000 m without derating 1000...3000 m with current derating 1 % per 100 m |