ZLL(ZXG)
SA5000
delivery time:1week
Product characteristics | |
---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
Process connection | threaded connection M18 x 1,5 Internal thread |
Application | |
System | gold-plated contacts |
Media | water; glycol solutions; air; oils |
Note on media | |
Medium temperature [°C] | -20...90 |
Pressure rating [bar] | 100 |
Pressure rating [Mpa] | 10 |
MAWP (for applications according to CRN) [bar] | 100 |
Electrical data | |
Operating voltage [V] | 18...30 DC |
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs | |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs | |
Total number of outputs | 2 |
Output signal | switching signal; analog signal; frequency signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 250 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 350 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Frequency of the output [Hz] | 0...1000 |
Measuring/setting range | |
Probe length L [mm] | 45 |
Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
Note on factory setting | |
Temperature monitoring | |
Measuring range [°C] | -20...90 |
Resolution [°C] | 0.2 |
Liquid media - absolute operating mode | |
Setting range [m/s] | 0.04...3 |
Greatest sensitivity [m/s] | 0.04...3 |
Liquid media - relative operating mode | |
Setting range [m/s] | 0.04...6 |
Greatest sensitivity [m/s] | 0.04...3 |
Gases - operating mode "absolute" | |
Setting range [m/s] | 0...100 |
Greatest sensitivity [m/s] | 30...100 |
Gases - operating mode "relative" | |
Setting range [m/s] | 0...200 |
Greatest sensitivity [m/s] | 30...100 |
Accuracy / deviations | |
Temperature drift [cm/s x 1/K] | 0,003 m/s x 1/K (< 20 °C; > 70 °C) |
Max. temperature gradient of medium [K/min] | 100 |
Absolute operating mode | |
Repeatability | 0,05 m/s; (water; Flow velocity: 0,05...3 m/s) |
Relative operating mode | |
Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
Repeatability | 0,05 m/s; (water; Flow velocity: 0,05...3 m/s) |
Temperature monitoring | |
Temperature drift | ± 0,005 K/°C |
Accuracy [K] | ± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s) |
Reaction times | |
Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature monitoring | |
Dynamic response T05 / T09 [s] | 1,5 (T09); (water; Flow velocity: 0,3...3 m/s) |
Software / programming | |
Parameter setting options | hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color |
Interfaces | |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |