HCM(YL)
XCSE5312
Delivery time:6 weeks
MAIN | |
---|---|
Range of product | Telemecanique Safety switches XCS |
Product or component type | Safety switch |
Component name | XCSE |
Design | Rectangular |
Material | Metal |
Head type | Key operated turret head |
Contacts type and composition | 1 NC + 2 NO |
Contact operation | Slow-break, break before make |
Solenoid contacts type and composition | 1 NC + 1 NO (slow-break, simultaneous) |
Cable entry | 2 entries tapped for M20 x 1.5 |
Electromagnet interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
[Us] rated supply voltage | 24 V - 20...10 % |
Cable outer diameter | 7…13 mm |
Electrical connection | Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end |
Number of poles | 3 |
Locking options description | With interlocking, locking by solenoid |
Local signalling | 2 LEDs (green or orange) for guard open/guard closed and locked |
Signalling circuit voltage | 24/48 V (voltage limits: 20...52 V) |
COMPLEMENTARY | |
Positive opening | With NC contact |
Supply voltage type | AC/DC |
Supply frequency | 50/60 Hz |
Load factor | 1 |
Power consumption in VA |
10 VA inrush 10 VA sealed |
Signalling circuit type | AC/DC |
Signalling circuit consumption | 7 mA |
Mechanical durability | 1000000 cycles |
Minimum actuation speed | 0.01 m/s |
Maximum actuation speed | 0.5 m/s |
[Ie] rated operational current |
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 |
[Ithe] conventional enclosed thermal current | 6 A |
[Ui] rated insulation voltage | 50 V conforming to EN/IEC 60947-1 for signalling circuit |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 |
Protection type | Overvoltage protection for signalling circuit |
Short-circuit protection | 10 A cartridge fuse type gG (gl) |
Actuator forcible withdrawal rtc | 2000 N |
Minimum actuator force for extraction | 20 N |
Maximum operating rate | 10 cyc/mn for maximum durability |
Safety level |
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Safety reliability data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Body material | Zamak |
Head material | Zamak |
Depth | 44 mm |
Height | 146 mm |
Width | 98 mm |
Net weight | 1.14 kg |
ENVIRONMENT | |
Standards |
UL 508 EN/ISO 12100 CSA C22.2 No 14 EN/IEC 60947-5-1 EN 1088/ISO 14119 EN/IEC 60204-1 |
Product certifications |
UL CSA |
Protective treatment | TC |
Ambient air temperature for operation | -25…40 °C |
Ambient air temperature for storage | -40…70 °C |
Vibration resistance | 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Electrical shock protection class | Class I conforming to EN/IEC 61140 |
IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |