HCM
XCK-J20513C
Delivery time:6 weeks
Main information
Product Series Telemecanique Limit switches XC Standard
Series Number Standard
Product Type Limit Switch
Product short name XCKJ
Sensor design Type A meets CENELEC EN 50041
Body type fixed type
Manipulator type Rotary head
Material Metal
Body material Zamak
Head material Zamak
Fixed mode by body
Operation head movement rotation
Operating head type Spring return roller Rocker metal
Method type Side motion, programmable in 1 or 2 directions
1 cable inlet hole suitable for M20x1.6 cable sealing interface, cable outer diameter: 7... 13 mm
Number of poles 2
Contact type 1 NC+1 NO
Contact action instantaneous
Supplementary information
Switch trigger 30 ° convex edge
Electrical connection screw clamp terminal, clamping force: 1 x 0.34... 2 x 1.5 mm ²
Contact wire insulation type Zb
Steps 1
Forced opening Yes
Forced opening minimum torque 0.5 N.m
Minimum triggering torque 0.25 N.m
Maximum operating speed 1.5 m/s
Rated operating current [Ie] 3 A at 240 V, AC-15, A300 in accordance with EN/IEC 60947-5-1, Appendix A
0.27 A on 250 V, DC-13, Q300 in accordance with EN/IEC 60947-5-1 Appendix A
Agreed closed thermal current [The] 10 A
Rated insulation voltage [Ui] 300 V in accordance with UL 508
500 V (pollution level 3) according to IEC 60947-1
300 V according to CSA C22.2 No 14
Maximum resistance across terminals 25 M Ω in accordance with IEC 60255-7 safety class 3
Rated impulse withstand voltage [Uimp] 6 kV in accordance with IEC 60664
6 kV according to IEC 60947-1
Short circuit protection 10 A fuse Fuse, type gG
Electrical life: 5000000 times, DC-13, inductive load type, 120 V, 4 W, operating rating<60 times/minute, load factor: 0.5 in accordance with IEC 60947-5-1, Appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rating<60 cycles/minute, load factor: 0.5 in accordance with IEC 60947-5-1, Appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rating<60 cycles/minute, load factor: 0.5 in accordance with IEC 60947-5-1, Appendix C
Mechanical life 30000000 times
Width 40 mm
Height 77 mm
Depth 44 mm
Net weight 0.49 kg
ISO n ° 1 terminal (21-22) NC
(13-14)NO
environment
Impact resistance 50 gn for 11 ms according to IEC 60068-2-27
Anti vibration 25 gn (f=10... 500 Hz) according to IEC 60068-2-6
IP protection level IP66 meets the requirements of threaded
IK protection level IK07 conforms to EN 50102
Overvoltage category I in accordance with IEC 61140
Class I complies with NF C 20-030
Operating temperature - 25... 70 ° C
Storage ambient temperature - 40... 70 ° C
Protection treatment TH
Product Certification CCC
Comply with standard CENELEC EN 50041
CSA C22.2 No 14
EN 60204-1
IEC 60204-1
IEC 60947-5-1
UL 508
EN 60947-5-1